PRODUCT DESCRIPTION
Application Area and Product Feature | |||||
● Explosion protection to -CENELEC -IEC -EN ● Can be applied in Zone 1, Zone2 Zone21, Zone22 ● Light source and power: Fluorescent tube (T8): 18W,36W Fluorescent tube (T5): 14W,28W LED module: 10W,20W,30W,36W ● Two enclosure types: -T8/T5 fluorescent tube: 18W×1,18W×2,14W×1,14W×2 LED tube: 10W×1, 20W×1, 30W×1, 36W×1 -T8/T5 fluorescent tube: 36W×1,36W×2,28W×1,28W×2 LED module: 20W×2,30W×2,36W×2 ● LED module is external power supply, LED light source and LED power is separate type; ● Factory equipped with tube or LED module when delivery; ●Central lock, built-in explosion-proof interlock switch, and switch of safety interlock will be off automatically while cover is opening; ●Emergency unit can be equipped upon request. | |||||
Explosion protection | Gas explosion protection | T8/T5 Fluorescent tube | II 2 G Ex db eb IIC T4 Gb | Ex db eb IIC T4 Gb | |
LED Module LED Module with emergency | II 2 D Ex db eb mb IIC T6 Gb | Ex db eb mb IIC T6 Gb | |||
T8/T5 Fluorescent tube with emergency | II 2 D Ex db eb mb IIC T4 Gb | Ex db eb mb IIC T4 Gb | |||
Dust explosion protection | II 2 D Ex tb ⅢC T80℃ Db | Ex tb ⅢC T80℃ Db | |||
Conformity to standards | IEC60079-0,IEC60079-1,IEC60079-7,IEC60079-18,IEC60079-31 EN60079-0, EN60079-1, EN60079-7, EN60079-18, EN60079-31 | ||||
Structure, Material | Enclosure | GRP, 7J impact resistance, corrosion resistance | |||
Diffuser | Polycarbonate, 7J impact resistance, high light transmittance | ||||
Ballast | Explosion-proof electronic ballast, wide voltage ourput (110~240VAC),power factor ≥0.95, with protection function of short circuit, overload, lamp aging, lamp damage and dissymmetry power of lamp tube. | ||||
LED Driver | Wide voltage input (100 ~ 250VAC), constant power output, power factor ≥0.95, with protection function of shunt, constant current, anti-surge, over-current, open circuit, short circuit, anti-electromagnetic interference. | ||||
Emergency unit | Explosion-proof emergency unit, when the power supply is off, the lamp will automatically switch to the emergency lighting state | ||||
Interlock | Ex interlock switch, safety interlock between enclosure and diffuser, when opening the transparent cover, the internal power supply is cut off reliably | ||||
Exposed fastener | Stainless steel | ||||
Light source | Specification | T8 fluorescent tube | T5 fluorescent tube | LED Module | |
Power (W) | 18W×1,18W×2 36W×1,36W×2 | 14W×1,14W×2 28W×1,28W×2 | 10W×1,20W×1, 30W×1,36W×1 20W×2,30W×2,36W×2 | ||
Rated voltage | T8 fluorescent tube:110~240V AC 50/60Hz | ||||
LED Module: 100~250V AC 50/60Hz | |||||
Degree of protection | IP66 | ||||
Ambient temperature | -20℃~+55℃,LED Module:-40℃~+55℃ | ||||
Terminal | 3×1.5~4mm2 (L+N+PE) | ||||
Cable entries | 4×φ25.2: 4-M25×1.5 | ||||
Available cable outer diameter | φ10~φ14(mm) | ||||
Emergency unit technical parameters | Emergency unit | Special emergency controller and battery pack, with with protection function of overcharge and overdischarge. | |||
Emergency power (W) | Fluorescent tube: 14W×1,18W×1,28W×1,36W×1 LED Module: 10W×1,10W×2 | ||||
Emergency starting time | 0.3s | ||||
Charging time | 24h | ||||
Emergency lighting time | 120min(180min Optional) |